Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

The following illustrates a standard operating procedure (SOP) for machining an NC file using the LaserCAM Symbiosis CNC.



Prerequisites

(tick) LaserCAM Symbiosis CNC

(tick) ViewRouter installed

(tick) UCCNC installed

(tick) UCCNC configured for the LaserCAM Symbiosis CNC

(tick) ViewRouter configured for the LaserCAM Symbiosis CNC

(tick) NC files present on local PC

Personal Protective Equipment (PPE)

(tick) Hearing protection

We recommend wearing hearing protection when operating the LaserCAM Symbiosis CNC.

Risks & Hazards

Environment

⚠ Slips, trips and falls

Please ensure that the environment is free from any obstruction or clutter and that surfaces are not slippery. Individuals operating equipment identity should first identify any environmental hazards that may place them or others at risk of injury.

Manufacture

(warning) Cutting hazard

(warning) Crush hazard

The LaserCAM Symbiosis CNC is housed within a safety enclosure. This safety enclosure does not allow for the machine to be in operation when the enclosure is open. Under no circumstance should the machine be operated with the enclosure open.

Goals

  • Turn on and prepare the LaserCAM Symbiosis CNC for machining
  • Load and run an NC file using UCCNC

Procedure

Turn on LaserCAM Symbiosis CNC

  1. Turn on LaserCAM Symbiosis CNC from green switch

  2. Wait 10 seconds for connection

Open UCCNC

  1. Open the Symbiosis shortcut

    1. This should be located on your desktop

    2. This is loads UCCNC with the correct configuration

Prepare LaserCAM Symbiosis

  1. Click green button on LaserCAM Symbiosis CNC safety enclosure

  2. Click flashing Reset button on UCCNC interface

  3. Click P1

  4. Click P2

  5. Click Diagnostics

  6. Disarm LaserCAM Symbiosis CNC

  7. Touch the Tool Probe on the router bit

  8. Ensure Probe light flashes green within UCCNC

  9. Place the Tool Probe within the circle on the LaserCAM Symbiosis CNC

  10. Click the Tool Probe button on the UCCNC

  11. Disarm LaserCAM Symbiosis CNC

  12. Remove the Tool Probe from the LaserCAM Symbiosis CNC

The LaserCAM Symbiosis CNC will now be referenced to the table surface.

Prepare EVA Blanks

  1. Prepare the required EVA blanks according to patient prescriptions

    1. Reference Orthosis Size (US Foot Size) and Density & Colour from patient prescription

    2. Apply double-sided tape to the plantar surface of all EVA blanks

  2. Adhere EVA blanks to the appropriate reference position on the LaserCAM Symbiosis CNC

    1. Reference positions will be marked P1, P2, P3 and P4

Please ensure that you press down firmly on the EVA blanks after placement on the LaserCAM Symbiosis CNC. Inadequate adhesion can result in machining hazard.

Load & Run NC File

  1. Arm LaserCAM Symbiosis CNC

  2. Click Load G Code in UCCNC

  3. Select your desired NC file

  4. Click Cycle Start in UCCNC

The selected NC files must have been generated using ViewRouter.

  • No labels