The following illustrates a standard operating procedure (SOP) for machining an NC file using the LaserCAM Symbiosis CNC2 Pair Pro, LaserCAM 6 Pair Pro and LaserCAM 12 Pair Pro CNC Systems.
...
Table of Contents |
---|
...
Prerequisites
LaserCAM Symbiosis CNC System
ViewRouter installed and configured
UCCNC installed
UCCNC configured for the LaserCAM Symbiosis CNC
ViewRouter configured for the LaserCAM Symbiosis CNC
NC files present on local PCand configured
Access to decrypted NC
files
Personal Protective Equipment (PPE)
Hearing protection
Note |
---|
We recommend wearing hearing protection when operating the your LaserCAM Symbiosis CNC System. |
Risks & Hazards
Environment
⚠ Slips, trips and falls
Info |
---|
Please ensure that the environment is free from any obstruction or clutter and that surfaces are not slippery. Individuals operating equipment identity should first identify any environmental hazards that may place them or others at risk of injury. |
Manufacture
Cutting hazard
Crush hazard
Info |
---|
The Your LaserCAM Symbiosis CNC System is housed within a safety enclosure. This safety enclosure does not allow for the machine to be in operation when the enclosure is open. Under no circumstance should the machine be operated with the enclosure open. |
Goals
- Turn on and prepare the your LaserCAM Symbiosis CNC System for machining
- Load and run an
NC
file using UCCNC
Procedure
Turn on LaserCAM
...
CNC System
Turn on LaserCAM Symbiosis CNC System from green switch
Wait 10 seconds for connection
Open UCCNC
Open the Symbiosis shortcut
This should be located on your desktop
This is loads UCCNC with the correct configuration
LaserCAM CNC System shortcut from your desktop
Prepare LaserCAM
...
CNC System
Click green button on LaserCAM Symbiosis CNC System safety enclosure
Click flashing Reset button on UCCNC interface
Click P1
Click P2
Click Diagnostics
Disarm LaserCAM Symbiosis CNC
Touch the Tool Probe on the router bit
Ensure Probe light flashes green within UCCNC
Place the Tool Probe within the circle on the LaserCAM Symbiosis CNC
Click the Tool Probe button on the UCCNC
Disarm LaserCAM Symbiosis CNC
Remove the Tool Probe from the LaserCAM Symbiosis CNC
Tip |
---|
Tip |
You are now ready to attach your EVA blanks or EVA blocks to the table surface. |
Prepare EVA Blanks
Prepare the required EVA blanks according to patient prescriptions
Reference Orthosis Size (US Foot Size) and Density & Colour from patient prescription
Apply double-sided tape to the plantar surface of all EVA blanks
Adhere EVA blanks to the appropriate reference position on the LaserCAM Symbiosis CNC System
Reference positions will be marked P1, P2, P3 and , P4, etc.
Tip |
---|
Please ensure that you press down firmly on the EVA blanks after placement on the LaserCAM Symbiosis CNC System. Inadequate adhesion can result in a machining hazard. |
Load & Run NC File
Arm LaserCAM Symbiosis CNC System
Click Load G Code in UCCNC
Select your desired the
NC
file that was generated using ViewRouterClick Cycle Start in UCCNC
Note |
---|
The selected |