The following illustrates a standard operating procedure (SOP) for configuring the LaserCAM Lab Code within LaserCAM Prescribe. This will ensure digital prescription are submitted to the correct laboratorymachining an NC file using the LaserCAM 2 Pair Pro, LaserCAM 6 Pair Pro and LaserCAM 12 Pair Pro CNC Systems.
...
Table of Contents |
---|
...
Prerequisites
...
Active internet connection
Your laboratories LaserCAM Lab Code
LaserCAM Prescribe installed
Goals
- Update LaserCAM Lab Code
- Optional: Submit digital prescription to laboratory
Procedure
Update LaserCAM Lab Code
Open LaserCAM Prescribe
Click the Settings icon from the top right corner and select Update Lab Code
Type in your laboratories LaserCAM Lab Code
Click OK
Tip |
---|
If LaserCAM Prescribe restarts, you have configured for your chosen laboratory. |
Optional: Laboratory Confirmation
It is recommended that you submit a test prescription to your configured laboratory.
Open LaserCAM Prescribe
Click New Prescription
You may pick any available prescription method
Click Patient Details
Enter a test name, e.g. - Test Submission
Click Review Prescription
Click Finalise Prescription → Finalise & Send to Lab
...
LaserCAM CNC System
ViewRouter installed and configured
UCCNC installed and configured
Access to decrypted NC
files
Personal Protective Equipment (PPE)
Hearing protection
Note |
---|
We recommend wearing hearing protection when operating your LaserCAM CNC System. |
Risks & Hazards
Environment
⚠ Slips, trips and falls
Info |
---|
Please ensure that the environment is free from any obstruction or clutter and that surfaces are not slippery. Individuals operating equipment identity should first identify any environmental hazards that may place them or others at risk of injury. |
Manufacture
Cutting hazard
Crush hazard
Info |
---|
Your LaserCAM CNC System is housed within a safety enclosure. This safety enclosure does not allow for the machine to be in operation when the enclosure is open. Under no circumstance should the machine be operated with the enclosure open. |
Goals
- Turn on and prepare your LaserCAM CNC System for machining
- Load and run an
NC
file using UCCNC
Procedure
Turn on LaserCAM CNC System
Turn on LaserCAM CNC System from green switch
Wait 10 seconds for connection
Open UCCNC
Open the LaserCAM CNC System shortcut from your desktop
Prepare LaserCAM CNC System
Click green button on LaserCAM CNC System safety enclosure
Click flashing Reset button on UCCNC interface
Click P1
Tip |
---|
You are now ready to attach your EVA blanks or EVA blocks to the table surface. |
Prepare EVA Blanks
Prepare the required EVA blanks according to patient prescriptions
Reference Orthosis Size (US Foot Size) and Density & Colour from patient prescription
Apply double-sided tape to the plantar surface of all EVA blanks
Adhere EVA blanks to the appropriate reference position on the LaserCAM CNC System
Reference positions will be marked P1, P2, P3, P4, etc.
Tip |
---|
Please ensure that you press down firmly on the EVA blanks after placement on the LaserCAM CNC System. Inadequate adhesion can result in a machining hazard. |
Load & Run NC File
Arm LaserCAM CNC System
Click Load G Code in UCCNC
Select the
NC
file that was generated using ViewRouterClick Cycle Start in UCCNC
Note |
---|
The selected |