The following illustrates a standard operating procedure (SOP) for configuring machining an NC file using the LaserCAM Lab Code within LaserCAM Prescribe. This will ensure digital prescription are submitted to the correct laboratory.Symbiosis CNC.

...

Table of Contents

...

Prerequisites

...

(tick) Active internet connection

(tick) Your laboratories LaserCAM Lab Code

(tick) LaserCAM Prescribe installed

Goals

  •  Update LaserCAM Lab Code
  •  Optional: Submit digital prescription to laboratory

Procedure

Update LaserCAM Lab Code

  1. Open LaserCAM Prescribe

  2. Click the Settings icon from the top right corner and select Update Lab Code

  3. Type in your laboratories LaserCAM Lab Code

  4. Click OK

Tip

If LaserCAM Prescribe restarts, you have configured for your chosen laboratory.

Optional: Laboratory Confirmation

It is recommended that you submit a test prescription to your configured laboratory.

  1. Open LaserCAM Prescribe

  2. Click New Prescription

    1. You may pick any available prescription method

  3. Click Patient Details

  4. Enter a test name, e.g. - Test Submission

  5. Click Review Prescription

  6. Click Finalise Prescription → Finalise & Send to Lab

...

(tick) LaserCAM Symbiosis CNC

(tick) ViewRouter installed

(tick) UCCNC installed

(tick) UCCNC configured for the LaserCAM Symbiosis CNC

(tick) ViewRouter configured for the LaserCAM Symbiosis CNC

(tick) NC files present on local PC

Personal Protective Equipment (PPE)

(tick) Hearing protection

Note

We recommend wearing hearing protection when operating the LaserCAM Symbiosis CNC.

Risks & Hazards

Environment

⚠ Slips, trips and falls

Info

Please ensure that the environment is free from any obstruction or clutter and that surfaces are not slippery. Individuals operating equipment identity should first identify any environmental hazards that may place them or others at risk of injury.

Manufacture

(warning) Cutting hazard

(warning) Crush hazard

Info

The LaserCAM Symbiosis CNC is housed within a safety enclosure. This safety enclosure does not allow for the machine to be in operation when the enclosure is open. Under no circumstance should the machine be operated with the enclosure open.

Goals

  •  Turn on and prepare the LaserCAM Symbiosis CNC for machining
  •  Load and run an NC file using UCCNC

Procedure

Turn on LaserCAM Symbiosis CNC

  1. Turn on LaserCAM Symbiosis CNC from green switch

  2. Wait 10 seconds for connection

Open UCCNC

  1. Open the Symbiosis shortcut

    1. This should be located on your desktop

    2. This is loads UCCNC with the correct configuration

Prepare LaserCAM Symbiosis

  1. Click green button on LaserCAM Symbiosis CNC safety enclosure

  2. Click flashing Reset button on UCCNC interface

  3. Click P1

  4. Click P2

  5. Click Diagnostics

  6. Disarm LaserCAM Symbiosis CNC

  7. Touch the Tool Probe on the router bit

  8. Ensure Probe light flashes green within UCCNC

  9. Place the Tool Probe within the circle on the LaserCAM Symbiosis CNC

  10. Click the Tool Probe button on the UCCNC

  11. Disarm LaserCAM Symbiosis CNC

  12. Remove the Tool Probe from the LaserCAM Symbiosis CNC

Tip

The LaserCAM Symbiosis CNC will now be referenced to the table surface.

Prepare EVA Blanks

  1. Prepare the required EVA blanks according to patient prescriptions

    1. Reference Orthosis Size (US Foot Size) and Density & Colour from patient prescription

    2. Apply double-sided tape to the plantar surface of all EVA blanks

  2. Adhere EVA blanks to the appropriate reference position on the LaserCAM Symbiosis CNC

    1. Reference positions will be marked P1, P2, P3 and P4

Tip

Please ensure that you press down firmly on the EVA blanks after placement on the LaserCAM Symbiosis CNC. Inadequate adhesion can result in machining hazard.

Load & Run NC File

  1. Arm LaserCAM Symbiosis CNC

  2. Click Load G Code in UCCNC

  3. Select your desired NC file

  4. Click Cycle Start in UCCNC

Note

The selected NC files must have been generated using ViewRouter.